Skip to content

Cummins DEF Delete Kit

Cummins DEF Delete Kit

Cummins DEF Delete Kit

Cummins DPF Delete Kit

Cummins DPF+DEF Delete Kit



Cummins DEF+DEF Delete Kit – your answer to costly DEF component failures and endless maintenance.
Designed to replace faulty NOx sensors, DEF pumps, DEF heaters, and all DEF-related components, this kit is the ideal upgrade for achieving reliability and efficiency without the constant interruptions caused by DEF system issues.

Installation couldn’t be easier. Thanks to its plug-and-play design, you can set it up quickly without technical expertise or reprogramming. This straightforward installation means you can skip the hassle and have your Cummins engine ready for optimal performance in no time.

Transform your engine’s capabilities and reduce downtime with the Cummins DEF Delete Kit. Don’t let faulty DEF components hold you back – invest today and keep your operation running smoothly and cost-effectively.


CUMMINS DEF Delete Kit – DPF BYPASS KIT


Imagine the difference: quicker job completions, enhanced fuel efficiency, and no hassles with DPF clogs slowing you down.
Say goodbye to unexpected service interruptions and costly maintenance tied to a clogged or malfunctioning DPF.
With this delete kit, you won’t just get continuous performance; you’ll enjoy smoother, faster operations, saving both time and money.

Cummins DPF Delete Kit

Cummins DPF Delete Kit



Cummins DPF Delete Kit – This kit is engineered for simplicity. With a plug-and-play design, installation is fast and effortless, allowing you to set it up within minutes. There’s no need for complex reprogramming or specialist skills, so you can get back to work without delay.
Once installed, your engine can operate at full efficiency without costly downtime for DPF maintenance or unexpected time-consuming regens.

By eliminating the need for DPF, you’ll save on fuel, reduce wear on your engine, and avoid recurring DPF-related issues that impact productivity.
Ideal for anyone seeking better fuel economy, reliable performance, and fewer interruptions.

  • Check if your model is supported by clicking here

Order now


Cummins DPF Delete Kit

Cummins DEF Delete Kit


Cummins DEF Delete Kit – is a game-changer for busy work environments. Boost your Cummins engine’s performance with the Plug-and-Play Cummins DPF Delete Kit, the ultimate solution for smoother, uninterrupted operation.

Imagine freeing your engine from DEF complications, leading to smoother operation and reduced maintenance expenses. With this Cummins DEF Delete Kit, there’s no need to worry about DEF fluid top-ups, heater malfunctions, or NOx sensor replacements. Instead, you gain continuous uptime and greater fuel efficiency, allowing you to focus fully on the job at hand.

Check if your model is supported by clicking here

Order now


Cummins DEF Delete Kit Installations

Cummins ISB45 engine – CUMMINS DEF DELETE KIT INSTALLATION.

Frequently asked questions

How does the emulator installation and DPF removal work?

Installation of the device is non-invasive, this is achieved thanks to the original plugs that the emulator is equipped with. The plugs match the ones from the machine. Komatsu/Cummins DPF filter removal with the help of our emulator is fully safe to the engine and does not require any interference with the engine controller whatsoever. After installing the device, the diesel particulate filter must be removed.

How does the installation of the emulator and removal of DPF and SCR work?

Similarly to the installation in machines with just the DPF the emulator must be connected using the plugs which the device is equipped with. Then disconnect the DEF pump controller and disconnect the nitrogen oxide sensors. Connect the emulators plug in the place of one of the NOx sensors, A detailed manual with a complete description of service steps is included in each order.

How does DPF regeneration work after filter removal?

The emulator simulates the operation of an efficiently working emission reduction system. The engine controller does not activate DPF regeneration because the signals generated by the emulator reports that the diesel particulate filter is in perfect condition.

Should I continue to add DEF (AdBlue) fluid?

No. The DEF/SCR pump no longer pumps the exhaust fluid. Refilling it is not necessary.

My machine has been diagnosed with a defective temparature sensor. Can I install this product?

Yes! Any sensor that monitor the operation of the DPF system becomes obsolete after installing the device, so the sensors can remain damaged or be removed completely.
Our Komatsu DEF emulator simulates the whole SCR system digitally, erasing related exhaust system error codes.


supported
Engines/Models

Engines
  • DPF only: SAA6D107E-2 (QSB6.7), SAA6D114E-5 (QSL9), SAA6D125E-6 (QSL11), SAA6D140E-6 (QSX15)
  • DPF+SCR/DEF: SAA6D107E-3 (QSB6.7), SAA6D114E-6 (QSL9), SAA6D125E-7 (QSL11), SAA6D170E-7 (23.1l), SAA12V140E-7 (30l)
Models
  • CASE: SV208, SV212, SV216
  • TEREX: TRT 70US, TRT 80US, TRT 100US
  • GROVE: GMK3050-3, GMK3060-2, GMK3060L-1, GMK7550
  • HITACHI: ZW180-6
  • LIEBHERR: R 920 Litronic
  • LEEBOY: CSV
  • SANY: SMHW45G5, SMG200, SCA1000A, SRC840, SRE600, SY 215 C, SY225C
  • SENNEBOGEN: 830M E, 821E HD, 624 HD, 1100, 690 HD, 1100E, 5500G, 6100E, 2200G, 655E, 640E
  • VERMEER: WC2500TX
  • HYUNDAI: HX160AL, HX180AL, HX210AL, HX380AL, 160D-9, Robex 140W, HX220AL, R 330LC-9A, HL940A, HL930A, HL940A, HL960A, HL955ATM
  • HITACHI: ZW140, ZW150PL‑6, ZW150‑6, ZW160-7, ZW370-G
  • DODGE: RAM
  • KALMAR: TT612D, T2 4×2, DCG160-12, DCG160-12, TT612D, DCG300-12LB, DCG120-6, DCG150-6, DRG100-54S6
  • CLAAS: TRION 520 BASIC
  • SVETRUCK: 15120-35
  • HYSTER: H10XM-ECD8, H16XM-6, H16XM-12, H16.00XM-12, H16XM-12
  • DYNAPAC: CC524HF, CA3500D, CA362D, CA3500D, CS142, SD 2500 CS, CA512D
  • LONKING: LG100 DT
  • HAMM: HC 119i
  • HYSTER: H14.00XM 6, H22XM-12EC
  • DETANK: DE220BLC
  • MECLIFT: ML1812R,
  • WIRTGEN: W100CFi
  • LIUGONG: 925E, 922E, CLG856H, 970E
  • SANY: SY265C
  • COMACCHIO: CH 320,
  • VÖGELE: 1800-3i Ergoplus, S 1803-3i
  • TERBERG: YT 182
  • TEREX: RT35
  • TANA: Shark 440DT
  • BAUER: BG 18 H
  • XCMG: XC958E
  • SHANTUI BULLDOZER: DH46-3
  • MACK: MD6 Chipper Box Truck
  • ISUZU: FTR
  • FREIGHTLINER BUSINESS CLASS: M2 106
  • LIUGONG: 4230D
  • KUBOTA: M8-181, M8-201
  • JCB: 419 S, 426 e HT, 426 e ZX, 427 Agri, 427 HT, 427 ZX, 435S, 436e ZX, 436e HT, 437 HT, 437 ZX, 455-4, 457 HT, 457S, 457 ZX
  • And many many more…

Emulated
Components

Click to expand
  • Diesel Particulate Filter (437-3512, 437-3551)
  • DEF Pump (591-2386, 546-2081, 546-2082, 485-9753, 398-4746, 398-4747) and Injectors (315-3381, 597-4344)
  • DEF tank temperature and level sensors (399-1211, 399-1209)
  • DEF Heater (473-2944)
  • Inlet / Outlet NOx sensors (421-7787, 441-5129, 441-5130, 539-0118)
  • Catalyst / DPF temperature sensors (460-7024, 377-6962, 314-3321, 415-2433, 334-1387, 436-0866, 383-2990)
  • DPF Differential pressure sensors (294-6118, 314-9772, 397-2874, 287-1960, 498-4187)
  • NH3 sensors for after 2017 models (421-7786)

Emission related
error codes

Click to expand
  • 1879-3251-3 Aftertreatment 1 Diesel Particulate Filter DifferentiaL Pressure Aftertreatment Diesel Particulate Filter Differentialal Pressure Sensor Circuit – Voltage below normal
  • 1881-3251-4 Aftertreatment 1 Diesel Particulate Filter DifferentiaL Pressure Aftertreatment Diesel Particulate Filter Differentialal Pressure Sensor Circuit – Voltage below normal
  • 1883-3251-2 Aftertreatment 1 Diesel Particulate Filter DifferentiaL Pressure Aftertreatment Diesel Particulate Filter Differential Pressure Sensor – Data erratic, intermittent or incorrect
  • 1921-3251-0 Aftertreatment 1 Diesel Particulate Filter DifferentiaL Pressure Aftertreatment Diesel Particulate Filter Differential Pressure – Data Valid But Above Normal Operating Range
  • 1922-3251-0 Aftertreatment 1 Diesel Particulate Filter DifferentiaL Pressure Aftertreatment Diesel Particulate Filter Differential Pressure – Data Valid But Above Normal Operating Range
  • 1981-3936-15 Aftertreatment Diesel Particulate Filter System Aftertreatment 1 Diesel Particulate Filter System – Data Valid But Above Normal Operating Range – Level
  • 1993-4795-31 Aftertreatment 1 Diesel Particulate Filter Missing Aftertreatment 1 Diesel Particulate Filter Missing – Condition Exists
  • 2639-3251-15 Aftertreatment 1 Diesel Particulate Filter Differential Pressure Aftertreatment Diesel Particulate Filter Differential Pressure – Data valid but above normal Operating Range
  • 2754-81-16 Engine Diesel Particulate Filter Intake Pressure Engine Diesel Particulate Filter Intake Pressure – Data Valid But Above Normal Operating Range – Moderately Severe Level
  • 2777-3703-31 Diesel Particulate Filter Active Regeneration Inhibited Due to Inhibit Switch Particulate Trap Active Regeneration Inhibited Due to Inhibit Switch – Condition Exists
  • 3133-3610-3 Aftertreatment Diesel Particulate Filter Outlet Pressure Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor Circuit – Voltage above normal, or shorted to high source
  • 3134-3610-4 Aftertreatment Diesel Particulate Filter Outlet Pressure Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor Circuit – Voltage above normal, or shorted to high source
  • 3135-3610-2 Aftertreatment Diesel Particulate Filter Outlet Pressure Aftertreatment 1 Diesel Particulate Filter Outlet Pressure – Data erratic, intermittent or incorrect
  • 3245-3936-7 Aftertreatment 1 Diesel Particulate Filter System Aftertreatment 1 Diesel Particulate Filter System – Mechanical system not responding or out of adjustment
  • 3253-3242-16 Aftertreatment 1 Diesel Particulate Filter Intake Gas temperature Aftertreatment 1 Diesel Particulate Filter Intake Temperature – Data Valid But Above Normal Operating Range
  • 3254-3242-15 Aftertreatment 1 Diesel Particulate Filter Intake Gas temperature Aftertreatment 1 Diesel Particulate Filter Intake Temperature – Data Valid But Above Normal Operating Range
  • 3255-3246-16 Aftertreatment 1 Diesel Particulate Filter Outlet Gas temperature Aftertreatment 1 Diesel Particulate Filter Intake Temperature – Data Valid But Above Normal Operating Range
  • 3256-3246-15 Aftertreatment 1 Diesel Particulate Filter Outlet Gas temperature Aftertreatment 1 Diesel Particulate Filter Intake Temperature – Data Valid But Above Normal Operating Range
  • 3311-3242-0 Aftertreatment 1 Diesel Particulate Filter Intake Gas temperature Aftertreatment 1 Diesel Particulate Filter Intake Temperature – Data valid but above normal operation
  • 3312-346-0 Aftertreatment 1 Diesel Particulate Filter Outlet Gas temperature Aftertreatment 1 Diesel Particulate Filter Outlet Temperature – Data valid but above normal operation
  • 3316-3242-4 Aftertreatment 1 Diesel Particulate Filter Intake Gas temperature Aftertreatment 1 Diesel Particulate Filter Intake Temperature Sensor Circuit – Voltage below normal, or shorted to low source
  • 3317-3242-3 Aftertreatment 1 Diesel Particulate Filter Intake Gas temperature Aftertreatment 1 Diesel Particulate Filter Intake Temperature Sensor Circuit – Voltage below normal, or shorted to low source
  • 3318-3242-2 Aftertreatment 1 Diesel Particulate Filter Intake Gas temperature Aftertreatment 1 Diesel Particulate Filter Intake Temperature – Data erratic, intermittent or incorrect
  • 3319-3246-3 Aftertreatment 1 Diesel Particulate Filter Outlet Gas temperature Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit – Voltage above normal, or shorted to high source
  • 3321-3246-4 Aftertreatment 1 Diesel Particulate Filter Outlet Gas temperature Aftertreatment 1 Diesel Particulate Filter Outlet Temperature Sensor Circuit – Voltage below normal, or shorted to low source
  • 3322-3246-2 Aftertreatment 1 Diesel Particulate Filter Outlet Gas temperature Aftertreatment 1 Diesel Particulate Filter Outlet Temperature – Data erratic, intermittent or incorrect
  • 3375-5397-31 Aftertreatment 1 Diesel Particulate Filter Regeneration too Frequent Aftertreatment Diesel Particulate Filter Regeneration too Frequent – Condition Exists
  • 3376-5319-31 Aftertreatment 1 Diesel Particulate Filter Incomplete Regeneration Aftertreatment Diesel Particulate Filter Incomplete Regeneration – Condition Exists
  • 3396-3750-31 Diesel Particulate Filter 1 Conditions Not Met for Active regeneration Diesel Particulate Filter 1 Conditions Not Met for Active Regeneration – Condition Exists
  • 3753-3713-31 Diesel Particulate Filter Active Regeneration Inhibited Due to System Timeout Diesel Particulate Filter Active Regeneration Inhibited Due to System Timeout – Condition Exists
  • 4151-5742-9 Aftertreatment Diesel Particulate Filter Temperature Sensor Module Aftertreatment Diesel Particulate Filter Temperature Sensor Module – Abnormal update rate
  • 4158-5742-12 Aftertreatment Diesel Particulate Filter Temperature Sensor Module Aftertreatment Diesel Particulate Filter Temperature Sensor Module – Bad intelligent device or component
  • 4161-5742-3 Aftertreatment Diesel Particulate Filter Temperature Sensor Module Aftertreatment Diesel Particulate Filter Temperature Sensor Module – Voltage Above Normal, or Shorted to high source
  • 4162-5742-4 Aftertreatment Diesel Particulate Filter Temperature Sensor Module Aftertreatment Diesel Particulate Filter Temperature Sensor Module – Voltage Above Normal, or Shorted to low source
  • 4163-5742-16 Aftertreatment Diesel Particulate Filter Temperature Sensor Module Aftertreatment Diesel Particulate Filter Temperature Sensor Module- Data Valid But Above Normal Operating Range
  • 4259-5742-11 Aftertreatment Diesel Particulate Filter Temperature Sensor Module Aftertreatment Diesel Particulate Filter Temperature Sensor Module – Root Cause Not Known
  • 4584-3936-14 Aftertreatment Diesel Particulate Filter System Aftertreatment Diesel Particulate Filter System – Special Instructions
  • 5938-3750-14 Diesel Particulate Filter 1 Conditions NotMet for Active regeneration Diesel Particulate Filter 1 Conditions Not Met for Active Regeneration – Condition Exists
  • 6265-3936-7 Aftertreatment 1 Diesel Particulate Filter System Aftertreatment 1 Diesel Particulate Filter System – Mechanical system not responding or out of adjustment
  • 6551-3610-3 Aftertreatment Diesel Particulate Filter Outlet Pressure Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor Circuit – Voltage above normal, or shorted to high source
  • 6552-3610-4 Aftertreatment Diesel Particulate Filter Outlet Pressure Aftertreatment 1 Diesel Particulate Filter Outlet Pressure Sensor Circuit – Voltage above normal, or shorted to low source
  • 6553-3610-2 Aftertreatment Diesel Particulate Filter Outlet Pressure Aftertreatment 1 Diesel Particulate Filter Outlet Pressure – Data erratic, intermittent or incorrect
  • 6596-3713-31 Diesel Particulate Filter Active Regeneration Inhibited Due to System Timeout Diesel Particulate Filter Active Regeneration Inhibited Due to System Timeout – Condition Exists
  • 1668-1761-4 Aftertreatment 1 Diesel Exhaust Fluid Tank level Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit – Voltage below normal, or shorted to low source
  • 1669-1761-3 Aftertreatment 1 Diesel Exhaust Fluid Tank level Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit – Voltage above normal, or shorted to high source
  • 1673-1761-1 Aftertreatment 1 Diesel Exhaust Fluid Tank level Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Data valid but below normal operational range -Most Severe level
  • 1677-3031-4 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Voltage below normal, or shorted to low source
  • 1678-3031-3 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Voltage below normal, or shorted to high source
  • 1679-3031-2 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature – Data erratic, intermittent or incorrect
  • 1682-3362-31 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input lines Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Input Lines – Condition Exists
  • 1683-3363-3 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Heater Aftertreatment 1 Diesel Exhaust Fluid Tank Heater – Voltage above normal, or shorted to high source
  • 1684-3363-4 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Heater Aftertreatment 1 Diesel Exhaust Fluid Tank Heater – Voltage above normal, or shorted to low source
  • 1685-3364-4 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit – Voltage below normal, or shorted to low source
  • 1686-3364-3 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality Sensor Circuit – Voltage below normal, or shorted to high source
  • 1699-1761-2 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor – Data erratic, intermittent or incorrect
  • 1712-3363-18 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Heater Aftertreatment 1 Diesel Exhaust Fluid Tank Heater – Data Valid But Below Normal Operating Range – Moderately Severe Leve
  • 1713-3363-16 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Heater Aftertreatment 1 Diesel Exhaust Fluid Tank Heater – Data Valid But Above Normal Operating Range – Moderately Severe Leve
  • 1714-3364-13 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality – Out of Calibration
  • 1715-64-11 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality – Root Cause Not Known
  • 2976-3361-2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Temperature – Data erratic, intermittent or incorrec
  • 3237-4340-4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 state Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit – Voltage above normal, or shorted to high source
  • 3238-4340-4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 state Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit – Voltage below normal, or shorted to low source
  • 3239-4342-3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 state Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit – Voltage above normal, or shorted to high source
  • 3241-4342-4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 state Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit – Voltage below normal, or shorted to low source
  • 3242-3363-7 Aftertreatment 1 Diesel Exhaust Fluid Tank1 Heater Aftertreatment 1 Diesel Exhaust Fluid Tank Heater – Mechanical system not responding or out of adjustment
  • 3258-4340-5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 state Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit – Current below normal or open circuit
  • 3261-4342-5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 state Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit – Current below normal or open circuit
  • 3422-4344-3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 3 state Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit – Voltage above normal, or shorted to high source
  • 3423-4344-5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 3 state Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit – Voltage below normal, or shorted to low source
  • 3425-4344-5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 3 state Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit – Current below normal or open circuit
  • 3497-1761-17 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Data Valid But Below Normal Operating Range – Least Severe Level
  • 3498-1761-18 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Aftertreatment 1 Diesel Exhaust Fluid Tank Level – Data Valid But Below Normal Operating Range – Moderately Severe Level
  • 3543-4094-31 NOx limits exceeded due to Insufficient Diesel Exhaust Fluid Quality NOx limits exceeded due to Insufficient Reagent Quality – Condition Exists
  • 3547-4096-31 NOx limits exceeded due to Empty Diesel Exhaust Fluid tank Aftertreatment Diesel Exhaust Fluid Tank Empty – Condition Exists
  • 3558-3361-3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit – Voltage above normal, or shorted to high source
  • 3559-3361-4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit – Voltage below normal, or shorted to low source
  • 3562-5491-3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater Relay Aftertreatment Diesel Exhaust Fluid Line Heater Relay – Voltage above normal, or shorted to high source
  • 3563-5491-4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater Relay Aftertreatment Diesel Exhaust Fluid Line Heater Relay – Voltage below normal, or shorted to low source
  • 3567-5394-7 Aftertreatment Diesel Exhaust Fluid Dosing Valve Aftertreatment Diesel Exhaust Fluid Dosing Valve – Current below normal or open circuit
  • 3568-5394-7 Aftertreatment Diesel Exhaust Fluid Dosing Valve Aftertreatment Diesel Exhaust Fluid Dosing Valve – Mechanical system not responding or out of adjustmen
  • 3571-4334-3 Aftertreatment 1 Diesel Exhaust Fluid Doser Absolute Pressure Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Voltage above normal, or shorted to high source
  • 3572-4334-4 Aftertreatment 1 Diesel Exhaust Fluid Doser Absolute Pressure Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Voltage below normal, or shorted to low source
  • 3574-4334-18 Aftertreatment 1 Diesel Exhaust Fluid Doser Absolute Pressure Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Valid But Below Normal Operating Range
  • 3575-4334-16 Aftertreatment 1 Diesel Exhaust Fluid Doser Absolute Pressure Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data Valid But Above Normal Operating Range
  • 3577-4376-3 Aftertreatment 1 Diesel Exhaust Fluid Return Valve Aftertreatment Diesel Exhaust Fluid Return Valve – Voltage above normal, or shorted to high sourc
  • 3578-4376-4 Aftertreatment 1 Diesel Exhaust Fluid Return Valve Aftertreatment Diesel Exhaust Fluid Return Valve – Voltage below normal, or shorted to low source
  • 3596-4334-2 Aftertreatment 1 Diesel Exhaust Fluid Doser Absolute Pressure Aftertreatment 1 Diesel Exhaust Fluid Pressure Sensor – Data erratic, intermittent or incorrect
  • 3713-5491-7 Aftertreatment 1 Diesel Exhaust Fluid LineHeater Relay Aftertreatment 1 Diesel Exhaust Fluid Line Heater Relay – Mechanical system not responding or out of adjustmen
  • 3755-5394-2 Aftertreatment Diesel Exhaust Fluid Dosing Valve Aftertreatment Diesel Exhaust Fluid Dosing Valve – Data erratic, intermittent or incorrect
  • 3866-3364-1 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality – Data valid but below normal operational range – Most Severe Level
  • 3867-3364-18 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality – Data Valid But Below Normal Operating Range – Moderate Severe Level
  • 3868-3364-9 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality – Abnormal update rate
  • 3876-3364-7 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality Sensor – Mechanical system not responding or out of adjustment
  • 3877-3364-12 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality Sensor – Bad intelligent device or component
  • 3878-3364-2 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality – Data erratic, intermittent or incorrect
  • 4155-5746-3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Relay Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Relay – Voltage Above Normal, or Shorted to high source
  • 4156-5746-4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Relay Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Relay – Voltage below normal, or shorted to low source
  • 4157-4376-7 Aftertreatment 1 Diesel Exhaust Fluid Return Valve Aftertreatment Diesel Exhaust Fluid Return Valve – Mechanical system not responding or out of adjust
  • 4168-5745-3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater – Voltage Above Normal, or Shorted to High
  • 4169-5745-4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater – Voltage below normal, or shorted to low source
  • 4171-5745-18 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater – Data Valid But Below Normal Operating Range
  • 4174-4337-3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature Sensor Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature Sensor – Voltage Above Normal, or Shorted to High Source
  • 4175-4337-4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature Sensor Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature Sensor – Voltage below normal, or shorted to low source
  • 4233-3515-3 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor Circuit – Voltage above normal, or shorted to high source
  • 4234-3515-4 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor Circuit – Voltage below normal, or shorted to low source
  • 4235-3521-31 Aftertreatment 1 Diesel Exhaust Fluid Property Aftertreatment 1 Diesel Exhaust Fluid Property – Condition Exists
  • 4242-3515-2 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 – Data erratic, intermittent or incorrect
  • 4243-3515-10 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Abnormal Rate of Change
  • 4244-4337-2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature – Data erratic, intermittent or incorrect
  • 4245-5798-2 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Temperature Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Temperature – Data erratic, intermittent or incorrect
  • 4249-4337-10 Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature – Abnormal Rate of Change
  • 4251-5798-10 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Temperature Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Temperature – Abnormal Rate of Change
  • 4277-3364-10 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality – Abnormal Rate of Change
  • 4486-5839-31 Diesel Exhaust Fluid Consumption Malfunction Diesel Exhaust Fluid Consumption Malfunction – Condition Exist
  • 4487-5841-31 Diesel Exhaust Fluid Dosing Malfunction Diesel Exhaust Fluid Dosing Malfunction – Condition Exists
  • 4488-5841-31 Diesel Exhaust Fluid Quality Malfunction Diesel Exhaust Fluid Quality Malfunction – Condition Exist
  • 4572-3031-9 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature – Abnormal Update Rate
  • 4573-3826-18 Aftertreatment 1 Diesel Exhaust Fluid Average Consumption Aftertreatment 1 Diesel Exhaust Fluid Average Consumption – Data Valid But Below Normal Operating Range
  • 4658-4331-18 Aftertreatment 1 Diesel Exhaust Fluid Actual Dosing Quantity Aftertreatment SCR Actual Dosing Reagent Quantity – Data Valid But Below Normal Operating Range – Mo
  • 4677-1761-9 Aftertreatment 1 Diesel Exhaust Fluid Tank Level SAE J1939 Multiplexing PGN Timeout Error – Abnormal update rate
  • 4679-1761-5 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit – Current below normal or open circui
  • 4682-3031-5 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor Circuit – Current below normal or open circuit
  • 4731-3031-13 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Out of Calibration
  • 4732-1761-13 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor – Out of Calibration
  • 4736-3031-6 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor Circuit – Current above normal or grounded circuit
  • 4737-3031-11 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature – Root Cause Not Known
  • 4738-1761-6 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor Circuit – Current above normal or grounded circuit
  • 4739-1761-11 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor – Root Cause Not Known
  • 4743-3515-5 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor Circuit – Current below normal or open circuit
  • 4744-3515-6 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Sensor Circuit – Current above normal or grounded
  • 4745-3515-11 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 – Root Cause Not Known
  • 4752-520716-3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Valve 1 heater Aftertreatment 1 Diesel Exhaust Fluid Dosing Valve 1 Heater – Voltage Above Normal, or Shorted to High Source
  • 4753-520716-4 Aftertreatment 1 Diesel Exhaust Fluid Dosing Valve 1 heater Aftertreatment 1 Diesel Exhaust Fluid Dosing Valve 1 Heater – Voltage Below Normal, or Shorted to Low Source
  • 4768-3521-11 Aftertreatment 1 Diesel Exhaust Fluid Property Aftertreatment 1 Diesel Exhaust Fluid Property – Root Cause Not Known
  • 4769-1761-10 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor – Abnormal Rate of Change
  • 4842-3364-15 Aftertreatment Diesel Exhaust Fluid Quality Aftertreatment Diesel Exhaust Fluid Quality – Data Valid But Above Normal Operating Range – Least Severe Level
  • 4863-5245-31 Aftertreatment Selective Catalytic Reduction Operator Inducement Active Aftertreatment Diesel Exhaust Fluid Tank Low Level Indicator
  • 5278-6802-31 Aftertreatment 1 Diesel Exhaust Fluid Dosing System Frozen – Condition Exists
  • 5866-520953-3 Aftertreatment Diesel Exhaust Fluid Dosing Unit Relay Feedback- Voltage Above Normal or Shorted to High Source.
  • 5867-520953-4 Aftertreatment Diesel Exhaust Fluid Dosing Unit Relay Feedback- Voltage Below Normal or Shorted to Low Source
  • 6475-3363-7 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Heater Aftertreatment 1 Diesel Exhaust Fluid Tank Heater – Mechanical system not responding or out of adjustment
  • 6476-3363-18 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Heater Aftertreatment 1 Diesel Exhaust Fluid Tank Heater – Data Valid But Below Normal Operating Range – Moderately Severe Level
  • 6477-5491-3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater Relay Aftertreatment Diesel Exhaust Fluid Line Heater Relay – Voltage above normal, or shorted to high source
  • 6478-5491-4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater Relay Aftertreatment Diesel Exhaust Fluid Line Heater Relay – Voltage below normal, or shorted to low source
  • 6479-3363-3 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Heater Aftertreatment 1 Diesel Exhaust Fluid Tank Heater – Voltage above normal, or shorted to high source
  • 6481-3363-4 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Heater Aftertreatment 1 Diesel Exhaust Fluid Tank Heater – Voltage below normal, or shorted to low source
  • 6482-4340-5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 State Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit – Current below normal or open circuit
  • 6483-4342-5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 State Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit – Current below normal or open circuit
  • 6484-4344-5 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 3 State Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit – Current below normal or open circuit
  • 6513-5745-17 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater – Data Valid But Below Normal Operating Range
  • 6526-1761-13 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor – Out of Calibration
  • 6527-4376-7 Aftertreatment 1 Diesel Exhaust Fluid Return Valve Aftertreatment Diesel Exhaust Fluid Return Valve – Mechanical system not responding or out of adjust
  • 6529-5746-3 Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Relay Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit Heater Relay – Voltage Above Normal, or Shorted to high source
  • 6531-4340-3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 State Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit – Voltage above normal, or shorted to high source
  • 6532-4340-4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 State Aftertreatment 1 Diesel Exhaust Fluid Line Heater 1 Circuit – Voltage below normal, or shorted to low source
  • 6533-4342-3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 State Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit – Voltage above normal, or shorted to high source
  • 6534-4342-4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 State Aftertreatment 1 Diesel Exhaust Fluid Line Heater 2 Circuit – Voltage below normal, or shorted to low source
  • 6535-4344-3 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 3 State Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit – Voltage above normal, or shorted to high source
  • 6536-4344-4 Aftertreatment 1 Diesel Exhaust Fluid Line Heater 3 State Aftertreatment Diesel Exhaust Fluid Line Heater 3 Circuit – Voltage below normal, or shorted to low source
  • 6537-5491-7 Aftertreatment 1 Diesel Exhaust Fluid Line Heater Relay Aftertreatment 1 Diesel Exhaust Fluid Line Heater Relay – Mechanical system not responding or out of adjustment
  • 6559-3031-4 Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Aftertreatment 1 Diesel Exhaust Fluid Tank Temperature Sensor – Voltage below normal, or shorted to low source
  • 6562-1761-11 Aftertreatment 1 Diesel Exhaust Fluid Tank Level Aftertreatment 1 Diesel Exhaust Fluid Tank Level Sensor – Root Cause Not Known
  • 6619-3515-10 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 Aftertreatment 1 Diesel Exhaust Fluid Temperature 2 – Abnormal Rate of Change
  • 6752-3364-18 Aftertreatment 1 Diesel Exhaust Fluid Tank 1 Quality Aftertreatment Diesel Exhaust Fluid Quality – Data Valid But Below Normal Operating Range – Moderately Severe Level
  • 4152-5743-9 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module Aftertreatment Selective Catalytic Reduction Temperature Sensor Module – Abnormal update rate
  • 4159-5743-4 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module Aftertreatment Selective Catalytic Reduction Temperature Sensor Module – Bad intelligent device or component
  • 4164-5743-3 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module Aftertreatment Selective Catalytic Reduction Temperature Sensor Module – Voltage Above Normal, or Shorted to high source
  • 4165-5743-4 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module Aftertreatment Selective Catalytic Reduction Temperature Sensor Module – Voltage below normal, or Shorted to low source
  • 4166-5743-16 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module Aftertreatment Selective Catalytic Reduction Temperature Sensor Module – Data Valid But Above Normal
  • 4261-5743-11 Aftertreatment Selective Catalytic Reduction Temperature Sensor Module Aftertreatment Selective Catalytic Reduction Temperature Sensor Module – Root Cause Not Known
  • 4143-5741-3 Aftertreatment 1 Outlet Soot Sensor Aftertreatment 1 Outlet Soot Sensor – Voltage Above Normal, or Shorted to High Source
  • 4144-5741-4 Aftertreatment 1 Outlet Soot Sensor Aftertreatment 1 Outlet Soot Sensor – Voltage below normal, or shorted to low source
  • 4153-5747-3 Aftertreatment 1 Outlet Soot Sensor Heater Aftertreatment 1 Outlet Soot Sensor Heater – Voltage Above Normal, or Shorted to High Source
  • 4154-5747-4 Aftertreatment 1 Outlet Soot Sensor Heater Aftertreatment 1 Outlet Soot Sensor Heater – Voltage below normal, or shorted to low source
  • 4449-5747-10 Aftertreatment 1 Outlet Soot Sensor Heater Aftertreatment 1 Outlet Soot Sensor Heater – Abnormal rate of change
  • 4451-5741-2 Aftertreatment 1 Outlet Soot Aftertreatment 1 Outlet Soot – Data erratic, intermittent or incorrect
  • 1694-3226-2 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor – Data erratic, intermittent or incorrect
  • 1885-3216-4 Aftertreatment 1 Intake NOx Aftertreatment 1 Intake NOx Sensor Circuit – Voltage below normal, or shorted to low source
  • 1887-3226-4 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor Circuit – Voltage below normal, or shorted to low source
  • 2771-3226-9 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor – Abnormal update rate
  • 3228-3216-2 Aftertreatment 1 Intake NOx Aftertreatment 1 Intake NOx Sensor – Data erratic, intermittent or incorrect
  • 3232-3216-9 Aftertreatment 1 Intake NOx Aftertreatment 1 Intake NOx Sensor – Abnormal update rate
  • 3543-4094-31 NOx limits exceeded due to Insufficient Diesel Exhaust Fluid Quality NOx limits exceeded due to Insufficient Reagent Quality – Condition Exists
  • 3545-3226-10 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor – Abnormal rate of change
  • 3547-4096-31 NOx limits exceeded due to Empty Diesel Exhaust Fluid Tank Aftertreatment Diesel Exhaust Fluid Tank Empty – Condition Exists
  • 3583-5031-10 Aftertreatment 1 Outlet Gas NOx Sensor Heater Ratio Aftertreatment 1 Outlet NOx Sensor Heater – Abnormal rate of change
  • 3649-5024-10 Aftertreatment 1 Intake Gas NOx Sensor Heater Ratio Aftertreatment 1 Intake NOx Sensor Heater – Abnormal rate of change
  • 3681-3228-2 Aftertreatment 1 Outlet NOx Sensor Power Supply – Data erratic, intermittent or incorrect
  • 3682-3218-2 Aftertreatment 1 Intake NOx Sensor Power Supply – Data erratic, intermittent or incorrect
  • 3717-3226-13 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor – Out of Calibration
  • 3718-3216-13 Aftertreatment 1 Intake NOx Aftertreatment 1 Intake NOx – Out of Calibration
  • 3725-3216-10 Aftertreatment 1 Intake NOx Aftertreatment 1 Intake NOx Sensor – Abnormal rate of change
  • 3748-3216-20 Aftertreatment 1 Intake NOx Aftertreatment 1 Intake NOx Sensor – Data not Rational – Drifted High
  • 3749-3226-7 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor – Data not Rational – Drifted High
  • 3988-3265-9 Aftertreatment 1 Outlet NOx Aftertreatment 2 Outlet NOx – Abnormal Update Rate
  • 4145-3255-9 Aftertreatment 1 Intake NOx Aftertreatment 2 Intake NOx Sensor – Abnormal update rate
  • 4452-520668-31 Aftertreatment 1 Outlet NOx Sensor Closed Loop Operation Aftertreatment 1 Outlet NOx Sensor Closed Loop Operation – Condition Exists
  • 6458-3216-20 Aftertreatment 1 Intake NOx Aftertreatment 1 Intake NOx Sensor – Data not Rational – Drifted High
  • 6459-3216-21 Aftertreatment 1 Intake NOx Aftertreatment 1 Intake NOx Sensor – Data not Rational – Drifted High
  • 6462-3226-20 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor – Data not Rational – Drifted High
  • 6463-3226-21 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor – Data not Rational – Drifted High
  • 6464-3226-2 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor – Data Erratic, Intermittant, or Incorrect.
  • 6521-3226-4 Aftertreatment Outlet NOx Sensor Circuits Aftertreatment Outlet NOx Sensor Circuit- Voltage below normal or shorted to low source
  • 6565-3226-10 Aftertreatment 1 Outlet NOx Aftertreatment 1 Outlet NOx Sensor – Abnormal rate of change
  • 6581-5031-10 Aftertreatment 1 Outlet Gas NOx Sensor Heater Ratio Aftertreatment 1 Outlet NOx Sensor Heater – Abnormal rate of change
  • 6582-3228-2 Aftertreatment 1 Outlet NOx Sensor Power Supply – Data erratic, intermittent or incorrect
  • 6621-3216-10 Aftertreatment 1 Intake NOx Aftertreatment 1 Intake NOx Sensor – Abnormal rate of change

Can’t Find your model? call us anyway